{"id":1047,"date":"2020-11-23T11:07:18","date_gmt":"2020-11-23T03:07:18","guid":{"rendered":"https:\/\/www.acooffice.com\/?p=1047"},"modified":"2022-03-25T16:28:13","modified_gmt":"2022-03-25T08:28:13","slug":"el-papel-aparece-completamente-negro-imprimiendo","status":"publish","type":"post","link":"https:\/\/www.acooffice.com\/es\/el-papel-aparece-completamente-negro-imprimiendo-html","title":{"rendered":"El papel aparece completamente negro al imprimir"},"content":{"rendered":"<p>1. El cable corona est\u00e1 roto<\/p>\n<p>Si el hilo corona est\u00e1 roto, sustit\u00fayalo.<\/p>\n<p>2. Falta el rodillo de carga o montaje defectuoso<\/p>\n<p>Si la impresi\u00f3n es completamente negra, puede deberse a la falta de rodillo de carga o a un montaje incorrecto. Esto suele deberse a una mala instalaci\u00f3n del cartucho de t\u00f3ner despu\u00e9s de extraerlo manualmente. En este momento, es necesario comprobar si hay alg\u00fan problema con el rodillo de carga y volver a montar el rodillo de carga.<\/p>\n<p>3. Mal contacto del soporte conductor del rodillo de carga o de la chapa de acero conductora.<\/p>\n<p>Si el soporte conductor del rodillo de carga o la chapa de acero conductora est\u00e1n en mal contacto, vuelva a montar el soporte conductor del rodillo de carga o la chapa de acero conductora y compruebe los puntos de contacto conductores en la m\u00e1quina.<\/p>","protected":false},"excerpt":{"rendered":"<p>1. The corona wire is broken If the corona wire is broken, replace the corona wire. 2. Missing charging roller or poor assembly If the printing is completely black, it may be due to missing charging roller or improper assembly. This is usually caused by poor installation of the toner cartridge after manual removal. At [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[],"series":[],"class_list":["post-1047","post","type-post","status-publish","format-standard","hentry","category-industry-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/posts\/1047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/comments?post=1047"}],"version-history":[{"count":0,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/posts\/1047\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/media?parent=1047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/categories?post=1047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/tags?post=1047"},{"taxonomy":"series","embeddable":true,"href":"https:\/\/www.acooffice.com\/es\/wp-json\/wp\/v2\/series?post=1047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}